| |+44 (0) 115 927 1721

Green & Yellow PVC Insulated Stranded Copper Conductors

An image of the green and yellow pvc insulated stranded copper conductor

A range of single core stranded class 2 plain annealed copper conductors with a heat resistant polyvinyl chloride (PVC) outer sheath. These non-armoured single insulation cables are often referred to as 6491X and are manufactured in accordance with specification BS 6004.

  • Harmonised Code H07V-R.
  • Voltage Rating 450/750V (designated suitable 600/1000V systems).
  • Heat Resistant PVC insulation complying with BS 7655 Type TI 1.
  • Operating Temperatures 0C to +70C.

Installation is not recommended for PVC below 0C as the compound may become brittle.

C.S.A. (sqmm)Stranding No. x Ø (mm)Nominal Ø (mm)Maximum Resistance @ 20C Ω/kmWeight per Metre (kg)Part Number
C.S.A. (sqmm)6Stranding No. x Ø (mm)7 x 1.04Nominal Ø (mm)4.8Maximum Resistance @ 20C Ω/km3.080Weight per Metre (kg)0.07Part NumberCPS 006
C.S.A. (sqmm)10Stranding No. x Ø (mm)7 x 1.35Nominal Ø (mm)6.1Maximum Resistance @ 20C Ω/km1.830Weight per Metre (kg)0.12Part NumberCPS 010
C.S.A. (sqmm)16Stranding No. x Ø (mm)7 x 1.70Nominal Ø (mm)7.1Maximum Resistance @ 20C Ω/km1.150Weight per Metre (kg)0.19Part NumberCPS 016
C.S.A. (sqmm)25Stranding No. x Ø (mm)7 x 2.14Nominal Ø (mm)8.9Maximum Resistance @ 20C Ω/km0.727Weight per Metre (kg)0.29Part NumberCPS 025
C.S.A. (sqmm)35Stranding No. x Ø (mm)7 x 2.52Nominal Ø (mm)10.1Maximum Resistance @ 20C Ω/km0.524Weight per Metre (kg)0.41Part NumberCPS 035
C.S.A. (sqmm)50Stranding No. x Ø (mm)19 x 1.78Nominal Ø (mm)11.8Maximum Resistance @ 20C Ω/km0.387Weight per Metre (kg)0.53Part NumberCPS 050
C.S.A. (sqmm)70Stranding No. x Ø (mm)19 x 2.14Nominal Ø (mm)13.6Maximum Resistance @ 20C Ω/km0.268Weight per Metre (kg)0.73Part NumberCPS 070
C.S.A. (sqmm)95Stranding No. x Ø (mm)19 x 2.52Nominal Ø (mm)15.9Maximum Resistance @ 20C Ω/km0.193Weight per Metre (kg)1.00Part NumberCPS 095
C.S.A. (sqmm)120Stranding No. x Ø (mm)37 x 2.03Nominal Ø (mm)17.5Maximum Resistance @ 20C Ω/km0.153Weight per Metre (kg)1.16Part NumberCPS 120
C.S.A. (sqmm)150Stranding No. x Ø (mm)37 x 2.25Nominal Ø (mm)19.4Maximum Resistance @ 20C Ω/km0.124Weight per Metre (kg)1.54Part NumberCPS 150
C.S.A. (sqmm)185Stranding No. x Ø (mm)37 x 2.52Nominal Ø (mm)21.7Maximum Resistance @ 20C Ω/km0.099Weight per Metre (kg)2.01Part NumberCPS 185
C.S.A. (sqmm)240Stranding No. x Ø (mm)61 x 2.25Nominal Ø (mm)24.5Maximum Resistance @ 20C Ω/km0.075Weight per Metre (kg)2.49Part NumberCPS 240
C.S.A. (sqmm)300Stranding No. x Ø (mm)61 x 2.52Nominal Ø (mm)27.5Maximum Resistance @ 20C Ω/km0.060Weight per Metre (kg)3.05Part NumberCPS 300
C.S.A. (sqmm)400Stranding No. x Ø (mm)61 x 2.85Nominal Ø (mm)30.9Maximum Resistance @ 20C Ω/km0.047Weight per Metre (kg)3.90Part NumberCPS 400

Material: Copper to BS EN 60228:2005.

PVC colour to BS 6746C.